| SOUND TESTING | STC | OITC RATINGS |
| Series 350 | 43 | 35 |
| Series 500 | 39 | 31 |
| Series 600 | 46 | 35 |
| SERIES 350 BLAST TEST RATING | ||
| ASTM HAZARD RATING | MINIMAL | |
| GSA PERFORMANCE CONDITION | 2 | |
| AVERAGE PEAK BLAST PRESSURE | 6.5 PSI | |
| AVERAGE POSITIVE PHASE IMPULSE | 45 PSI –MSEC | |
| AVERAGE POSITIVE PHASE DURATION | 15 MSEC | |
| SERIES 800 IMPACT TEST RATINGS MISSILE LEVEL D WIND ZONE 4 LARGE MISSILE IMPACT | ||
| Dbl CASEMENT | 60 PSF | |
| FIXED | 60 PSF | |
| FIXED/CASEMENT | 60 PSF | |
| PROJECT OUT | 60 PSF | |